rtx1™ Adaptive Optics Retinal Camera* – specifications***
|
|
|
|
The tables below provides overall specifications*** for the rtx1™ Adaptive Optics Retinal Camera*. | Imaging specifications - Imaging type
- En face reflectance imaging
- Illumination type
- Flashed, non-coherent flood illumination
- Central illumination wavelength
- 850 nm (infrared)
- Detection type
- Low noise CCD camera
- Frame rate
- 9.5 fps
- Camera pixel resolution
- 1.6 µm 1
- Transverse optical resolution
- 250 line pairs per millimeter (lppmm) 1,2
- Imaging field of view
- 4° x 4° 1
- System field of view
- ±30° from locus of fixation1, 3
H ±9° / V ±7° from locus of fixation 1, 4 - Image file format
- PNG (Portable Network Graphic)
| | | | Adaptive optics specifications - Spherical ametropia compensation range
- -12 / +6 D
- Focusing range
- 600 µm 1
- Adaptive optics control
- Fully automated, highly-resistant to blinking
- Adaptive optics illumination
- 750 nm (infrared) SLED (SuperLuminescent Diode)
| | | | Other system specifications - Pupil diameter range
- 4 - 10 mm
- Working distance
- 50 mm
- Internal fixation target
- Miniature OLED display
- Internal fixation target gaze angle (max)
- H ±9° / V ±7°
- External fixation target type
- LED attached to chinrest
- Software interface
- rtx1 software suite with the following functionalities: system control, ametropia compensation, pupil alignment, image acquisition, and image processing.
| | | | General specifications - Intended use
- Research Use Only 5
- Dimensions (instrument head only)
- L 35 x W 17.5 x H 50 cm
- Weight (instrument head only)
- 13 Kg
- Optical power output
- Infrared, ISO 15004-2:2007 classification group 1
(no potential hazard) - Input voltage
- Medical-grade isolation transformer
100-130 & 220-240 AC / 50-60 Hz Transformer complies with EN60601-1 standard - Output voltage
- PC: 12 VDC / 0.5 A
Adaptive optics electronics driver: -1 VDC to +1 VDC / 2A
| - Some specifications are dependent on ocular biometry, pupil diameter, optical defects, ocular media transparency as well as other factors.
- System can image line pairs of 2 µm in line width.
- Using external fixation target.
- Using internal fixation monitor.
- The rtx1 is intended for research use only (RUO). Not for use in diagnostic procedures. It is neither FDA 510(k) cleanered nor CE marked for use in diagnostic procedures.
| | | Click to here to download these specifications to your computer in PDF format. To be kept informed of news, publications and other advances, click here. To view images acquired using the rtx1, click here. For more information or, if you are interested in becoming an investigational partner site, please contact Laurent Vabre via e-mail by clicking here or by telephone on +33 (0)1 64 86 15 66.
|